SafeGuard® CryptoServer PCIe Technical Data 1 SafeGuard CryptoServer Se-Series PCIe (Models Se10 and Se50)

Dimensions
Operating power
3,3 volt (PCI Express bus specification) Power requirements
3 V, Lithium, Ø 12 mm, length 600 mm, Sanyo CR 12 600 SE or identical type, e.g. VARTA CR2NP External interfaces
2 serial V.24 interfaces 2 USB 2.0 interfaces (high speed) In operation: +10 C to +45° C (+50° F to +113° F) Environmental temperature
In warehouse: -10° C to +55° C (+14° F to +131° F) Humidity
10 to 95 % relative humidity, non-condensing 360,000 hours (in acc. with MIL-HDBK-217) RoHS, WEEE
RoHS compliant, Elektro-Altgeräte-Register DE39805015 EMC emission: EN 55022 class B EMC immunity: EN 61000-6-2 (industrial environment) Equipment safety: IEC/EN 60950-1 (CB scheme) Compliance
FCC 47 CFR Ch. 1 Part 15 class B Climatic and mechanical conditions: ETSI EN 300 019 Storage Class 1.1, Transportation class 2.1 (with temperature range limited to temperature in warehouse as defined above), stationary use at weather protected locations class 3.1 SafeGuard® CryptoServer PCIe Technical Data 2 SafeGuard CryptoServer Se-Series PCIe (Models Se400 and Se1000)

Dimensions
Operating power
3,3 volt (PCI Express bus specification) Power requirements
3 V, Lithium, Ø 12 mm, length 600 mm, Sanyo CR 12 600 SE or identical type, e.g. VARTA CR2NP External interfaces
2 serial V.24 interfaces 2 USB 2.0 interfaces (high speed) In operation: +10° C to +45° C (+50° F to +113° F) Environmental temperature
In warehouse: -10° C to +55° C (+14° F to +131° F) Humidity
10 to 95 % relative humidity, non-condensing 360,000 hours (in acc. with MIL-HDBK-217) RoHS, WEEE
RoHS compliant, Elektro-Altgeräte-Register DE39805015 EMC emission: EN 55022 class B EMC immunity: EN 61000-6-2 (industrial environment) Equipment safety: IEC/EN 60950-1 (CB scheme) Compliance
FCC 47 CFR Ch. 1 Part 15 class B Climatic and mechanical conditions: ETSI EN 300 019 Storage Class 1.1, Transportation class 2.1 (with temperature range limited to temperature in warehouse as defined above), stationary use at weather protected locations class 3.1 SafeGuard® CryptoServer PCI Technical Data 3 Technical data for SafeGuard CryptoServer CS-Series PCI

Dimensions
Operating power
3,3 and 5,0 volt (PCI bus specification) Power requirements
3 V, Lithium, Ø 12 mm, length 600 mm, Sanyo CR 12 600 SE or identical type, e.g. VARTA CR2NP External interfaces
In operation: +10 C to +35 C / +50 F to +95 F Environmental temperature
In warehouse: -10° C to +55° C / +14 F to +131 F Humidity
10% to 95% relative humidity, non-condensing 350,000 hours (in acc. with MIL-HDBK-217) ROHS, WEEE
RoHS compliant, Elektro-Altgeräte-Register DE39805015 EMC emission: EN 55022 class B EMC immunity: EN 61000-6-2 (industrial environment) Equipment safety: IEC/EN 60950-1 (CB scheme) Compliance
FCC 47 CFR Ch. 1 Part 15 class B Climatic and mechanical conditions: ETSI EN 300 019 Storage Class 1.1, Transportation class 2.1 (with temperature range limited to temperature in warehouse as defined above), stationary use at weather protected locations class 3.1

Source: http://promate.pl/doc/utimacosetechnical.pdf

Untitled

Biological Warfare — An Emerging ThreatReshma Agarwal*, SK Shukla**, S Dharmani***, A Gandhi***As we approach the 21st century, there is an increasing worldwide awareness and threat regarding theuse of biological warfare agents both for war and terrorist attack. Biological agents include microorganismsor biological toxins that are used to produce death in humans, animals and plants. They are c

Ch3094

CH-3094 (AUG 04) Page 1 of 4 INDIANA UNIVERSITY HOSPITAL PHYSICIAN ORDER SET ADULT PROSTATECTOMY POST-OPERATIVE (Page 1 of 4) Confidential Information Protected USE BALL POINT PEN (PRESS FIRMLY) By Indiana Peer Review Act Orders must be signed and dated to be active. Pre-printed orders need to be checked by the physician to verify appropriateness for a particular patient an